chinacoal11
http://www.chinacoalintl.com/
http://m.chinacoalintl.com/
http://china-machinary.com/
we provide service of enterprise's customs declaration, inspection.Application:By using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.
Features:
1.New wavelet analysis and processing technique, effective extraction of the pile bottom reflection signal;
2. Real-time automatic processing of the testing waveform (smoothing, integr al, filtering wave, index, linear magnification, etc.);
3.Signal superposition and averaging, “noise” reduction, superposition signal can be viewed at any time, delete the poor quality signal;
4.P810 can connect with both speed probe and acceleration probe;
5. Photoelectric knob + shortcut keys, making the operation more convenient and fast, testing hundreds of piles in one day
6.Standard USB port, copy data to a memory card, this port can also be used to update software;
7.Battery lifetime of 5 hrs;
8.Professional analysis software for Windows operating system is available. This software is fully featured, and it can produce detailed testing reports. Print settings are flexible, print preview and print processed result;
iItem
|
ZBL-P810
| |
Working mode
|
Independently
| |
Control mode
|
Industrial dedicated control system
| |
Monitors
|
6.4 inch high brightness, TFT LCD monitor
| |
Storage method
|
256M+U disk
| |
Sentinel magnify (time)
|
1, 10, 100 adjustable
| |
Floating point magnify (time)
|
256
| |
A/D resolution (bit)
|
24 bits (16 bits A/D+8 bits floating point)
| |
Sampling time intervals(μs)
|
5μs ~ 64ms adjustable
| |
Max length of sampling
|
³1024
| |
Trigger
|
Signal trigger, external trigger
| |
Operation method
|
Photoelectrical knob + shortcut
| |
Noise voltage of the system (mV)
|
≤2
| |
Dynamic range (dB)
|
184
| |
Amplifier frequency range (Hz)
|
10Hz ~ 10kHz
| |
Max storage length
|
1024
| |
Amplitude nonlinear degree
|
≤10%
| |
Time value error
|
≤1%
| |
Time resolving power
|
5μs
| |
Gain error
|
≤ 1dB
| |
Continuous working time
|
> 5hrs
| |
Number of channels
|
2
| |
Consistency of phase position of two channels
|
±3°
| |
Consistency of amplitude of two channels
|
≤3%
| |
Interference between the channels
|
≤1%
| |
Transducer/Probe Sensitivity
|
Acceleration probe (mv/g)
|
≥100
|
Frequency range of Probe
|
Acceleration probe
|
0.5 ~ 9000 Hz
|
Transmission port
|
Standard USB, mobile storage available
| |
Electricity supply
|
AC: 220V±10%, DC +15V
| |
Weight
|
1.8 kg (including internal lithium battery)
| |
Size
|
252mm × 185mm ×58mm
| |
Working environment
|
0℃ ~ +40℃; air humidity<90%RH
|