2017年7月20日星期四

ZBL-P810 Foundation Pile Dynamic Detecting Machine

chinacoal11
http://www.chinacoalintl.com/
http://m.chinacoalintl.com/
http://china-machinary.com/
we provide service of enterprise's customs declaration, inspection.
ApplicationBy using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.
Features:
1.New wavelet analysis and processing technique, effective extraction of the pile bottom reflection signal;
2. Real-time automatic processing of the testing waveform (smoothing, integr al, filtering wave, index, linear magnification, etc.);
3.Signal superposition and averaging, “noise” reduction, superposition signal can be viewed at any time, delete the poor quality signal;
4.P810 can connect with both speed probe and acceleration probe;
5. Photoelectric knob + shortcut keys, making the operation more convenient and fast, testing hundreds of piles in one day
6.Standard USB port, copy data to a memory card, this port can also be used to update software;
7.Battery lifetime of 5 hrs;
8.Professional analysis software for Windows operating system is available. This software is fully featured, and it can produce detailed testing reports. Print settings are flexible, print preview and print processed result;
iItem
ZBL-P810
Working mode
Independently
Control mode
Industrial dedicated control system
Monitors
6.4 inch high brightness, TFT LCD monitor
Storage method
256M+U disk
Sentinel magnify (time)
1, 10, 100 adjustable
Floating point magnify (time)
256
A/D resolution (bit)
24 bits (16 bits A/D+8 bits floating point)
Sampling time intervals(μs)
5μs ~ 64ms adjustable
Max length of sampling
³1024
Trigger
Signal trigger, external trigger
Operation method
Photoelectrical knob + shortcut
Noise voltage of the system (mV)
≤2
Dynamic range (dB)
184
Amplifier frequency range (Hz)
10Hz ~ 10kHz
Max storage length
1024
Amplitude nonlinear degree
≤10%
Time value error
≤1%
Time resolving power
5μs
Gain error
≤ 1dB
Continuous working time
 5hrs
Number of channels
2
Consistency of phase position of two channels
±3°
Consistency of amplitude of two channels
≤3%
Interference between the channels
≤1%
Transducer/Probe Sensitivity
Acceleration probe (mv/g)
≥100
Frequency range of Probe
Acceleration probe
0.5 ~ 9000 Hz
Transmission port
Standard USB, mobile storage available
Electricity supply
AC: 220V±10%, DC +15V
Weight
1.8 kg (including internal lithium battery)
Size
252mm × 185mm ×58mm
Working environment
0℃ ~ +40℃; air humidity90%RH