www.chinacoalintl.com
m.chinacoalintl.com
we provide service of enterprise's customs declaration, inspection.
ZBL-P8100 concrete rebar detector, concrete rebar detector, rebar detector
Main Parameter
By using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.
Hammer instrument: use different types of hammer (different energy/material) for different types of piles (lengths, etc.)
Features:
1.Large touch screen, user friendly interface, easy to learn and master
2.Dual-channel simultaneous sampling, multi-directional testing for each pile makes the work more efficiently
3.Wavelet processing can effectively collect reflecting signal from pile bottom, exceeds international standards
4.The systems advanced design accurately stores the wave form image, and multiple channel signals can be saved for each tested pile
5.Real time on-site test wave can be treated with smoothing, differential, filtering, power exponent and linear amplification wave processing methods
6.The signal noise can be eliminated by taking the superposition of multiple signals. The superposition can be viewed at any time, allowing the poorer quality signals to be ignored
7.Files arranged by projects piles; clear and convenient, project/pile testing data can be easily accessed, edited, or deleted
8.Standard USB port, thumb drive can be used for updating software; convenient and reliable
Main Parameter
Item
|
Specifications
|
Item
|
Specifications
|
Control Mode
|
Embedded platform,
WinCE Operation System
|
Monitor
|
8.4 inch,high brightness,TFT Color LCD
|
Data storage
|
2GB,SD card
|
Operation Mode
|
Touch screen
|
Trigger
|
Signal trigger
|
Ports
|
USB port
|
Noise voltage of the system
|
≤2 mV
|
Dynamic range
|
³184 dB
|
Amplifier frequency range
|
1Hz~10kHz
|
Input impedance
|
³1 MW
|
Sampling time intervals
|
6µs~64ms
|
Time resolution
|
6µs
|
Max length of sampling
|
³1024
|
Gain error
|
≤1 dB
|
Amplitude nonlinear degree
|
≤10%
|
Timing accuracy
|
≤1%
|
Floating point magnification (time)
|
1~256
|
Sentinel magnify (time)
|
1~1,000,adjustable
|
A/D resolution
|
16 bit A/D,8 bit floatingpoint
|
Max magnify (times)
|
256000
|
Number of channels
|
2
|
Transducer sensitivity
|
³100 mv/g(acceleration mode)
|
Consistency of phase position
of two channels
|
±3° or 0.05ms
|
Frequency range of
Transducer
|
0.5~9000 Hz(acceleration mode)
|
Amplitude consistency of two channels
|
≤3% or ≤±0.2dB
|
Continuous operating hours
|
>5 hrs
|
Interference between channels
|
≤1%
|
Power
|
AC:220V±10%,DC:+12V
|
Dimensions
|
256mm´188mm´63.5mm
|
Weight
|
2.3kg(lithium battery included)
|