2015年12月21日星期一

ZBL P8100 Concrete Rebar Detector

chinacoal11
www.chinacoalintl.com
m.chinacoalintl.com
we provide service of enterprise's customs declaration, inspection.
 ZBL-P8100 concrete rebar detector, concrete rebar detector, rebar detector
Main Parameter
By using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.

Hammer instrument: use different types of hammer (different energy/material) for different types of piles (lengths, etc.)
  
Features:

1.Large touch screen, user friendly interface, easy to learn and master

2.Dual-channel simultaneous sampling, multi-directional testing for each pile makes the work more efficiently

3.Wavelet processing can effectively collect reflecting signal from pile bottom, exceeds international standards

4.The systems advanced design accurately stores the wave form image, and multiple channel signals can be saved for each tested pile

5.Real time on-site test wave can be treated with smoothing, differential, filtering, power exponent and linear amplification wave processing methods

6.The signal noise can be eliminated by taking the superposition of multiple signals. The superposition can be viewed at any time, allowing the poorer quality signals to be ignored

7.Files arranged by projects   piles; clear and convenient, project/pile testing data can be easily accessed, edited, or deleted

8.Standard USB port, thumb drive can be used for updating software; convenient and reliable

Main Parameter
Item
Specifications
Item
Specifications
Control Mode
Embedded platform, 
WinCE Operation System
Monitor
8.4 inch,high brightness,TFT Color LCD
Data storage
2GB,SD card
Operation Mode
Touch screen
Trigger
Signal trigger
Ports
USB port
Noise voltage of the system
≤2 mV
Dynamic range
³184 dB
Amplifier frequency range
1Hz~10kHz
Input impedance
³1 MW
Sampling time intervals
6µs~64ms
Time resolution
6µs
Max length of sampling
³1024
Gain error
≤1 dB
Amplitude nonlinear degree
≤10%
Timing accuracy
≤1%
Floating point magnification (time)
1~256
Sentinel magnify (time)
1~1,000,adjustable
A/D resolution
16 bit A/D,8 bit floatingpoint
Max magnify (times)
256000
Number of channels
2
Transducer sensitivity
³100 mv/g(acceleration mode)
Consistency of phase position
 of two channels
±3° or 0.05ms
Frequency range of 
Transducer
0.5~9000 Hz(acceleration mode)
Amplitude consistency of two channels
≤3% or ≤±0.2dB
Continuous operating hours
>5 hrs
Interference between channels
≤1%
Power
AC:220V±10%,DC:+12V
Dimensions
256mm´188mm´63.5mm
Weight
2.3kg(lithium battery included)