http://www.chinacoalintl.com/
http://m.chinacoalintl.com/
http://china-machinary.com/
we provide service of enterprise's customs declaration, inspection.
Device description
Oxygen sensor SS1118 (0~100%)
- With high concentrated oxygen measuring sensor, only for the Oxygen generator and medical sensor
- Measure the oxygen’s pressure in the air
Oxygen sensor SS2118 (0~30%)
- As the measuring sensor of the oxygen in the air, suitable for the portable equipment and industrial equipment
- Excellent accuracy and response time
Carbon monoxide sensor SS1128
- Fire monitoring application for the portable equipment, industrial safety equipment, boiler room, parking place
- Excellent stability of the output signal and little ffected by other gases
Hydrogen sulfide sensor SS1198
- Suitable to monitor the petrochemical, oil refining, waste water treatment, drain water treatment, manhole, mining
IR (Infrared) Sensor
- Gas measuring Sensor only for the flammable gas and carbon dioxide, nitrogen dioxide
- The Infrared sensor which has Very fast response and excellent accuracy can easure the flammable gas in the nonoxygen space
Hydrogen sensor SS1178
- Suitable to monitor the power plant, hydrogen fuel battery, hydrogen tank, hydrogen leakage and processes
- Minimize the interference on the hydrogen sulfide
Specification
Model
|
SS1118
|
SS2118
|
SS1128
|
SS1198
|
SS1178
|
SS11N8
|
IR
| |
Detecting Gas
|
Oxygen
|
Oxygen
|
Carbon monoxide
|
Hydrogen sulfide
|
Hydrogen
|
Ammonia
|
Hydro Carbon, CO₂etc
| |
Nominal Range
|
0~100%
|
0~30%
|
0~1,000ppm
|
0~500ppm
|
0~1,000ppm
|
0~100ppm
|
0~5%Vol
| |
Maximum Overload
|
-
|
-
|
2,000ppm
|
1,000ppm
|
2,000ppm
|
200ppm
|
0~100%
| |
Expected Operating Life (years)
|
18 month
|
2
|
2
|
2
|
2
|
2
|
5
| |
Output Signa
|
6.0±1.0mV
|
90±20㎂@/20.9% Oxygen
|
60±15nA/ppm
|
0.60±0.15㎂
|
15±10nA/ppm
|
100±20nA/ppm
|
0-2.8V DC
| |
Resolution
|
0.1%
|
0.5%
|
1ppm
|
0.1ppm
|
2ppm
|
1ppm
|
0.5%
| |
Temperature Range
|
-20℃~+50℃
| |||||||
Pressure Range
|
Atmospheric ±10%
| |||||||
T90 Response Time
|
≤15 sec
|
≤15 sec
|
≤30 sec
|
≤30 sec
|
≤30 sec
|
<60 sec
|
≤30 sec
| |
Relative Humidity Range
|
15~90%RH
|
0~90%RH
| ||||||
Typical Baseline Range
|
-
|
-
|
-2 to 3ppm
|
-0.1 to 0.5ppm
|
0 to 30ppm
|
0 to 2ppm
|
0 to 10ppm
| |
Expected Operating Life (years)
|
-
|
-
|
-2 to 3ppm
|
0.2ppm Equivalent
|
-20ppm Equivalent
|
3ppm Equivalent
|
10ppm Equivalent
| |
Long Term
|
Less than
|
Less than
|
Less than
|
Less than
|
Less than
|
Less than
|
±1%FSDper
| |
Output Drift
|
5%/year
|
5%/year
|
5%/year
|
5%/year
|
5%/month
|
2%/month
|
month@20℃
| |
Recommended LoadResistor
|
-
|
100Ω
|
10Ω
|
10Ω
|
10Ω
|
33Ω
|
-
| |
Bias Voltage
|
Not required
|
Not required
|
Not required
|
Not required
|
Not required
|
Not required
|
-
| |
Repeatability
|
2% of signal
|
2% of signal
|
2% of signal
|
2% of signal
|
2% of signal
|
10% of signal
|
-
| |
Output Linearity
|
Linear
| |||||||
Weight
|
7g
|
18g
|
6g
|
6g
|
4.5g
|
15g
| ||
Position Sensitivity
|
None
| |||||||
Storage Life
|
6 month
| |||||||
Recommended Storage Temperature
|
0~20℃
| |||||||
Warranty Period
|
1 years
|
2 years
|
2 years
|
2 years
|
2 years
|
2 years
|
2 years
|
没有评论: